AED Cuer5

Print
Priced From:R 46728,00
aed cu-er58
Description

PARAMEDIC SERIES AED

MANUAL MODE DEFIBRILLATOR / MONITOR

EXTERNAL ADULT & PEDIATRIC PADDLES

CU-ER5

 

FEATURES:

 - Manual Mode – 20 steps escalating

- AED Mode – 150J into a 50Ω load.

- Reusable External Paddle (Adult, Pediatric) & Multifunction Defib. Pads

- ECG Monitoring Mode (3 Lead, 5 Lead), SpO2 Monitoring

- Heart Rate & SpO2 Alarm System

- Automatic and operator initiated self tests

 

         SPECIFICATIONS:

MODEL:

CU-ER5

Defibrillation:

ECG Lead Select

Waveform

Maxiumum Shock

Output Energy

 

 

Energy Accuracy

Charge Time

Shock Delivery

 

Patient impedance

AED Mode

Synchronous Cardioversion

Voice & Text

Prompts (AED)

I, II, III, aVR, aVL, aVF, V, Paddle/Pads, Ext ECG

Truncated Exponential Biphasic

20ms

Manual:  1~10J, 15j, 20J, 30J, 50J, 70J, 100, 120, 150J, 170J, 200J

AED Mode (Single energy output):  150J

Internal Paddle::  1~10J, 15J, 20J, 30J, 50J

1~10J : ±2J, 15~200J : ±15%

Less than 12 seconds to 200 Joules

Via multifunction defib electrode pads

External paddle (pediatric) or internal paddle (pediatric)

Shock Range : 25Ohm ~ 175Ohm

Shock advisory sensitivity and specificity meet AAMI DF-80 guidelines

Pads or External paddle, External ECG input

Voice & text prompts guide the user through the protocol

All the user interfaces are supported in local language for easy use and access

ECG Monitor:

Input

 

 

Lead Fault

 

Heart Rate Display

ECG size

Heart Rate Alarm

Lead I,II, III obtained through 3-lead ECG cable separate monitoring electrodes

With 5-lead cable obtain leads I, II, III, aVR, aVL, aVF, or V

“Lead Fault” message and dashed line displayed, if an electrode or lead wire becomes disconnected.

30 to 300bpm (±3bpm)

5, 10, 20mm/mV and Auto-gain

Less than Minimum setting rate / Over the Maximum setting rate

SpO2 Pulse Oximetry (Nellcor)

Saturation

Pulse Rate

70-100% (± 3 digits)

20-250bpm (±3bpm)

0.2%

Less than Miniumum setting rate / Over than maxiumum setting rate

Power source

Internal Battery – Rechargeable / 12V 4.2Ah Nickel-Metal Hydride battery pack

Capacity – when new, minimum of 200 shock deliveries (200J)

Minimum of 4 hours for full charging

External Battery Pack – Disposable /12V 4200mAH Lithium battery pack

Capacity – when new, minimum of 200 shock deliveries (200J)

AC/DC Adapter – Input : 100 – 240V AC 50/60Hz 170VA

Output – DC 12V, 3.6A

Car Cigar Lighter

Jack DC 12V

Physical

Dimensions  - Without external paddle : 254* 365*105(mm)

With External paddle :  455*365*105(mm)

Weight; 3.5kg (without Paddle)

Environmental Requirement

Temperature

 

Humidity

Operation: 0°C ~ 40°C

Storage: -20°~ 60°C

5% ~ 95%

Data Storage & Management

Internal flash memory: 12 hours of event and ECG recording

SmartMedia Card (32M): 42 hours of event and ECG recording or 1 hour if voice recording is enabled.

Transmit multi patient data to PC  UART/ IrDA

Display

LCD Dimensions - 4” diagonal (80mm*60mm)

High Resolution Mono Graphic LCD
Resolution - 320* 240 pixels

Wave Viewing Time - 3.2 seconds (ECG)

Sweep Speed - 25mm/sec

Back light -  EL Back Light

Automated Self-Test

- Power On Self-Test / Run Time Self-Test / Manual Test

- Periodic Self-Tests (daily / weekly / monthly)

Standard Accessories

-  Device

-  External Paddle (Adult, pediatric)

-  3-lead ECG Cable

-  Power cord

-  AC Adapter

-  Internal Battery (Ni-MH)

-  User’s Guide

Optional Accessories

-  Date Card (SMC 32M)

-  Thermal Printer

-  Printer Paper (10 rolls)

-  Cigar Lighter Jack for Car

-  Multifunction Defib. Pads

-  Adapter for Defib. Pads

-  5-Lead ECG Cable

-  ECG Electrodes (50EA)

-  SPO2 Module Set (Probe, Extension Cable)

-  Disposable Battery Pack (lim02)

-  IrDA Adapter for Data Communication

-  Software for Data Management with Key File (UART cable included)