P Monitor SF

Print
Priced From:R 30491,56
Description

PATIENT MONITOR SF

 

Features:

- 12.1” Colour TFT display, CRT or larger display can be connected simultaneously.

- AC Power and internal rechargeable battery

- 13 kinds of Arrhythmia analysis, HRV and S-T segment analysis

- 60 seconds ECG waveform review

- 7-Channel ECG waveforms displayed simultaneously

- Drug dose calculation

- Maximum 72-hour graphic and tabular trends of all Parameters

- Adjustable 3 level audio and visual alarm

- Anti-high-frequency electrosurgical equipment

- Optional with Built-in 3 channels thermal recorder.  External Printer can be connected

- Networked with central monitoring system by wired or wireless LAN

- Applicable for Adult, Pediatric and Neonatal patient

 

SPECIFICATIONS:

MODEL:

SF

Display:

12.1 Inch Diagonal

800 x 600 Pixel Colour TFT

Displayed Parameters:

Time:

Alarms:

ECG:

Heart Rate:

NIBP:

Pulse Oximeter:

Respiration Rate:

Trends:

Temperatures:

Trace Freeze:

Battery-backed quartz crystal clock

High & low limits selectable on patient parameters

ECG Waveform Scale

Derived from ECG or SPO2

Pressure (systolic, mean and diastolic)

Pulse Rate, Pulse waveform and percent saturation

Respiration rate derived from ECG

HR, RR, NIBP, ST, TEMP, CO2 and SPO2

Two Channels

Traces A & B

ECG:

 

Display Gain Scales:

 

Sweep Speed:

Input Resistance:

Frequency Response:

CMRR:

Electrode Offset Potential:

Baseline Recovery:

Heart Rate Range:

Resolution:

Accuracy:

Alarm:

Lead off condition:

Protected against defibrillator and electro surgery potentials

Standard Lead, I, II, III, aVL, aVR, aVF, Vx

2.5mm/mV, 5mm/mV, 7mm/mV, 10mm/mV, 15mm/mV, 20mm/mV, 25mm/mV

6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s

>5M Ohm (at 10Hz, not including patient cable)

0.05Hz – 100Hz (3dB)

>80dB

Maximum ±0.3V

15bpm – 300bpm

1bpm

Heart rate high and low limits alarm delay <12s

Detected and displayed

ST Segment range:

Accuracy:

-1.2mV to +1.2mV

±0.02mV

SPO2:

 

 

LED Specifications:

 

 

Alarm Display:

Display Update:

Resolution:

Range:  0% - 100%

Accuracy:  80% - 100%  ±2 digits, 70%-80% ±3digits, 0-69% unspecified

                     Wavelength         Radiant Power

RED             660±2nm               1.8mW   

IR                 905±10nm             2.0mW

SPO2 high and low limits alarm delay <7s

<5s

1%

Pulse Rate:

Measurement Range:

Resolution:

Accuracy:

Alarm delay:

20 to 250bpm

1bpm

±1bpm

Pulse rate high and low limits alarm delay <7s

NIBP:

Technique:

 

Patient Types:

Cuff Inflation Time:

Cuff inflation pressure:

 

Measurement Modes:

 

 

 

First Inflation Measurement:

Oscillometric method (with inflatable cuff)

Determines systolic,diastolic and mean arterial pressures

Adult, Pediatric and Neonatal

3-15s depending on cuff size

Adult/Pediatric/Neonatal, subsequent inflation pressure determined by last measured systolic pressure

Manual:  Immediate upon operator command

AUTO:  Determinations automatically made with selectable intervals

STAT:  Determinations continues in 5 minutes

Adult/Pediatric/Neonatal

Measurement Interval Time:

1 – 240min

Step:  1 min (1min – 10min), 5min (10 min – 30min)

          10 min (30min – 90min), 30min (90 – 240min)

Measurement Range:

Adult

Systolic: 30mmHg – 225mmHg

Diastolic:15mmHg – 220mm Hg

Mean Arterial:  20mmHg~235mmHg

Measurement Range:

Infant

Systolic:  30mmHg – 135mmHg

Diastolic: 15mmHg – 110mmHg

Mean Arterial:  20-125mmHg

Pressure Resolution:  1mmHg

Accuracy:

Cuff Pressure Range:  0 to 275mmHg

Pressure Span Accuracy:  ±3mmHg

Mean difference:  ±5mmHg

Standard deviation:  8mmHg

Determination Time:

Typically 25s.  Varies with patient’s pulse rate, pulse pressure and amount of artifact present

Overpressure Valve:

Automatically releases cuff pressure if inflation pressure exceeds 280mmHg/150mmHg

Overtime Protection:

Stop determinates if the measurement time exceeds 120s/90s

Alarm Delay:

Pressure high and low limits alarm delay <7s

RR:

Technique:

Range:

Resolution:

Accuracy:

Alarm delay:

Trans-thoracic impedance (RA-LL)

0-100 rpm

1 rpm

± 2 rpm (0-60rpm)

Respiration rate high and low limits alarm delay <7s

Temperature:

Technique:

Channel:

Scales:

Probes:


Range:

Revolution:

Accuracy:

Alarm delay:

Resistance

2 (T1 and T2)

F. or C.

Resistive, recta and skin (reusable and disposable)

YSI 400 Series types

0-50°C

0.1°C

±0.1°C

Body temperature high and low limits alarm delay <7s

CO2 (Optional):

 

IBP (Optional):

 

Power Requirements:

100-240VAC, 50/60Hz  1.6A max

Internal Battery:

12V 7AH, typed-sealed lead-acid

Operating Time:

2 hours typical at 25°C, no printing, one NIBP measurement

(fully charged battery):

Per 15 min

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarm Range:

Upper Range:  HR 40-300pbm    Lower Range:20-160

Systolic:           (kpa)12-34            Systolic:          (kpa) 8-29.3

                        (mmHg) 90-255                            (mmHg) 60-220

Diastolic:         (kpa) 8-29.3           Diagsolic:       (kpa) 4-24

                       (mmHg) 60-220                            (mmHg) 30-180

Mean Arterial  (kPa) 4.6-29.3      Mean Arterial: (kPa) 4-26.6

                       (mmHg) 35-220                            (mmHg) 30-200

SPO2 (%)       80 – 100               SPO2 (%)       70 – 99

RR (bpm)       10 – 120                RR (bpm)        5 – 80

Temp (°C)      25.5 – 45         &nbs